Where Does the Load Go? 7 Wood-Framed Load Paths Engineers Should Check

Designing an individual beam, post, or shear wall is only part of the job. The forces still need a complete path through the building.

In wood-framed structures, that load path can become less obvious when walls don’t stack, diaphragms cantilever, openings interrupt shear walls, or lateral forces transfer into gravity framing.

Here are seven load paths worth checking in your wood building model.

1. What happens when a shear wall sits on a beam?

A shear wall reaction doesn’t stop at the bottom of the wall. When the wall is supported by a beam, those forces become part of the beam design and continue into the supporting structure below.

Depending on the condition, this can include shear wall reactions, overturning forces, and seismic forces requiring the overstrength factor (Ω).

In LAVA: The shear wall and supporting beam are connected in the model so the applicable forces can be carried into the beam design. Learn more about LAVA handles this situation: Discontinuous Lateral Walls

Check: Are you designing the beam for all of the forces coming from the shear wall, or just its gravity loads?

Shear wall sitting on a Beam

2. How does diaphragm force reach an interior shear wall?

Shear walls aren’t always located at the exterior edge of the diaphragm. Large windows, balconies, and open exterior walls can push the lateral system farther into the building.

The diaphragm then needs a load path to transfer those forces to the interior shear wall line.

In LAVA: Diaphragm supports can be defined based on the intended building layout, including single and double cantilever diaphragm conditions in a Rigid diaphragm. Check out a full description of how LAVA handles Cantilever Diaphragm.

Check: Does your diaphragm model represent where the lateral support actually occurs?

Cantilever Rigid Diaphragm

3. Where does a collector force go?

Calculating the collector force is only the beginning. That force still needs to travel through the collector, into the shear wall, and through the connections along the way.

The collector may also be a beam carrying gravity loads, making the interaction between the gravity and lateral systems important.

In LAVA: Collector forces are tracked as part of the lateral load path and can be carried into the supporting framing.

Check: Once you’ve calculated the collector force, can you follow where it goes next?

Collector forces in wood diaphragm

4. What happens when shear walls don’t stack?

This is a common condition in real wood buildings. An upper-story shear wall may land over a beam, an opening, or a completely different wall configuration at the level below.

That means the lateral forces need to be transferred before they can continue down the building.

In LAVA: Engineers define how the building is detailed and how those forces transfer between levels. LAVA then tracks the applicable forces through the defined load path. You can see exactly what’s connected to what and make modifications if you don’t agree with how it’s connected.

Check: If the wall above disappeared from your plan, could you clearly show how its forces reach the lateral system below?

Discontinuous shear walls

5. Where do overturning forces go?

A hold-down doesn’t make overturning disappear. Its tension force needs a continuous load path into the structure below.

In multi-story wood buildings, that may involve hold-downs, straps, posts, bearing plates, or a continuous tie-down system, with forces accumulating as they travel down the building.

In LAVA: Overturning restraint is included in the shear wall design, and continuous tie-down systems can be tracked through multiple levels.

Check: Can you follow the overturning load path from the upper shear wall all the way down?

6. How do forces get around openings in a shear wall?

Doors and windows interrupt the direct load path through a wall. How those forces get around the opening depends on the shear wall design method.

Segmented shear walls, perforated shear walls, and force transfer around openings (FTAO) each handle the wall and its openings differently.

In LAVA: Engineers can model different approaches for shear walls with openings so the wall design reflects the intended load path.

Check: Does your analysis method match how the forces are actually expected to travel around the opening?

FTAO Wood Wall

7. Once diaphragm force reaches a shear line, where does it go?

Getting the diaphragm force to the shear line isn’t the end of the analysis. A shear line may contain multiple wall segments with different lengths, stiffnesses, and capacities.

The total force still needs to be distributed among those individual wall segments.

In LAVA: Shear lines can distribute forces using stiffness-based or capacity-based methods, giving engineers control over how the force is assigned to the individual walls.

Check: Do you know how much force each wall segment is actually carrying?

Shear Line with diaphragm loads

Can You Follow the Load Through Your Model?

The individual calculations in a wood building may not be the hardest part. The challenge is often making sure the forces get from one element to the next.

LAVA connects gravity and lateral design while still giving the engineer control over how the building is detailed and how the load path is defined.

The software handles the calculations. The engineer defines the load path.

Want to see how LAVA follows these forces through a wood-framed building? Schedule a Demo with LAVA Software and we’ll walk through the load path together.

See how LAVA fits into your next project

Questions? Contact us at info@cbs2llc.com